What environmental considerations are there? Last Updated: 05/23/2014
Typical environmental temps for the motor should be run in a low humidity environment with an ambient temperature range of –20 C to +50 C. BLDC motors do have IP ratings associated to them and limited customization can be done to increase the IP rating. If severe conditions require IP ratings of IP54 or higher, a customized motor construction is required to accommodate this need.